<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-24 00-18-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 59 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 61 kHz 19060 0,1469
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 3,18 dBr 4,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 0:18, 24.10.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 61 kHz MIN: 10 kHz % above 76 kHz: 0,1469 Acquired: 2025/10/24 0.17.32 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,4 dBr MIN: 0,9 dBr AVE: 3,18 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/10/24 0.17.31) 00.04 00.06 00.08 00.10 00.12 00.14 00.16 0 2 4 Pm [dBr]